=====Problem Description : Error: The device is not in the current IRF ===== * **Product Model # : 4800G** * Software / Firmware version : 5.20 2202 * Fact : Attempting to add an IRF device to a stack, that was previously configured or misconfigured. 1.- Resetting the device back to factory defaults does not remove the IRF number **ERROR: The device is not in the current IRF.** Unable to add a new device to an IRF Stack Cause : If a device has been previously configured with an incorrect member ID or does not match the stack member ID, the new device will not synchronize with the existing stack. Fix : Use the following command to determine the current Member ID 4800G]dis irf conf MemberID NewID IRF-Port1 IRF-Port2 *4 4 1 2 ---- * indicates the device is the master. + indicates the device through which the user logs in. Undo irf member 4 renumber Undo irf member 4 irf-port 1 Undo irf member 4 irf-port 2 4800G]dis irf conf MemberID NewID IRF-Port1 IRF-Port2 *4 1 disable disable ---- * indicates the device is the master. + indicates the device through which the user logs in. Save Reboot Then issue the commands Irf member 1 renumber 3 Irf member 1 irf-port 1 port 1 Irf member 1 irf-port 2 port 2 Save Reboot Connect the new unit to the IRF Stack.