hpe:switch:5500:configuration:changing_time_control_may_not_remove_qos_rules_at_right
CHANGING THE TIME CONTROL MAY NOT REMOVE QOS RULES AT THE RIGHT TIME
Goals: Changing the time control may not remove QoS rules at the right time System time changed
Fixes: The QoS Access list rules can be automatically applied or removed at a specific time of day. If the system time is changed then the time control may not function correctly until the first transition has occured e.g.
If a rule is to be applied at 09:00 and the system clock is changed at 08:00 to 10:00 then the rule will not be applied until 23 hours later i.e. at the following day 09:00.
Product(s): Switch 5500, Switch 5500G Sub Product(s): Switch 5500-SI, Switch 5500-EI
— David Gonzalez 2021/03/29 14:23