VSU UPGRADE

Note:Applicable for all chassis/box switches

Scenario: One VSU group is consist of two S8600 VSU group, each of the chassis is loaded with dual control engine.

1. Network Topology

2. Configuration Tips

2.1. Read release notes before the upgrade, especially the "supported hardware list"

2.2. VSU upgrade will cause network service down, plz researve at least TWO hours for the upgrade process.

3. Configuration Steps

3.1. Backup config file to local PC

3.2. Confirm hardware version before upgrade

3.3. Confirm with customer if service download is allowed;

3.4. Change chassis from VSU to standalone mode

Ruijie-ACTIVE#switch convert mode standalone

3.5. Follow chapter "firmware upgrade>User mode upgrade"

3.6. Show version on both chassis

3.7. Convert chassis back to VSU mode

Ruijie#switch convert mode virtual

Convert switch mode will automatically backup the “config.text” file and then delete it, and reload the switch. Do you want to convert switch to virtual mode? [no/yes]y

Do you want to recover “config.text” from “virtual_switch.text” (press 'ctrl + c' to cancel) [yes/no]:y

3.8. (show switch virtual), check network production